R-CAS-V Spin-In Capsule with Threaded Rods
High-performance, quick-setting, styrene-free vinylester resin for concrete
Features and benefits
- Approved for use with threaded rods in non-cracked concrete (ETAG001 Option 7)
- High performance for use safety critical application - heavy-duty fastenings with small spacing and edge distances
- The system relies on the adhesion between the concrete and resin, which is free from expansion forces. This makes it an ideal choice where close edge and spacing distances are required
- Capsule contains precise amounts of ingredients making it a very consistent product
- Suitable for dry or wet non-cracked concrete
- Styrene free - odourless
Product information
Product Code |
Description / Resin Type |
R-CAS-V-08 |
Styrene Free Vinylester Resin |
R-CAS-V-10 |
Styrene Free Vinylester Resin |
R-CAS-V-12 |
Styrene Free Vinylester Resin |
R-CAS-V-16 |
Styrene Free Vinylester Resin |
R-CAS-V-20 |
Styrene Free Vinylester Resin |
R-CAS-V-24 |
Styrene Free Vinylester Resin |
R-CAS-V-30 |
Styrene Free Vinylester Resin |
Base material
-
Non-cracked concrete C20/25-C50/60
For use also with
-
Natural Stone (after site testing)
Applications
- Threaded rods
- Balustrading
- Railings
- Heavy machinery
- Structural steel
- Steel columns
- Cladding restraints
- Curtain walling
- Fencing & gates manufacturing and installation
- Formwork support systems
- Garage doors
- Guard rails
Installation guide
- Drill hole to the required diameter and depth for capsule size being used.
- Clean the hole thoroughly with brush and hand pump at least four times before installation.
- Insert capsule into the hole. Connect stud to drilling machine using appropriate driver system.
- Position the stud into the glass capsule then switch on the drilling machine and drive stud into the capsule. Switch off the drilling machine as soon as the bottom of hole is reached.
- Leave the anchor undisturbed unitl the curing time elapses.
- Attach fixture and tighten the nut to the required torque.
Installation data
R-STUDS
Size |
M8 |
M10 |
M12 |
M16 |
M20 |
M24 |
M30 |
||
Thread diameter |
d |
[mm] |
8 |
10 |
12 |
16 |
20 |
24 |
30 |
Hole diameter in substrate |
d0 |
[mm] |
10 |
12 |
14 |
18 |
24 |
28 |
35 |
Capsule size |
[mm] |
8 |
10 |
12 |
16 |
20 |
24 |
30 |
|
Capsule diameter |
dc |
[mm] |
9.25 |
10.75 |
12.65 |
16.75 |
21.55 |
23.75 |
33.2 |
Installation torque |
Tinst |
[Nm] |
10 |
20 |
40 |
80 |
120 |
180 |
300 |
Min. hole depth in substrate |
h0 |
[mm] |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
hnom + 5 |
Min. installation depth |
hnom |
[mm] |
80 |
90 |
110 |
125 |
170 |
210 |
270 |
Min. substrate thickness |
hmin |
[mm] |
120 |
130 |
140 |
180 |
230 |
270 |
340 |
Min. spacing |
smin |
[mm] |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
Min. edge distance |
cmin |
[mm] |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
0.5 * hnom ≥ 40 |
Minimum working and curing time
Resin temperature |
Concrete temperature |
Curing time* |
Working time |
[°C] |
[°C] |
[min] |
[min] |
5 |
-5 |
480 |
- |
5 |
0 |
240 |
- |
5 |
5 |
150 |
- |
10 |
10 |
120 |
- |
15 |
15 |
90 |
- |
20 |
20 |
45 |
- |
25 |
30 |
20 |
- |
25 |
40 |
10 |
- |