Something went wrong... Please try again.
R-RB Rawlbolt® Shield
World's most popular all-purpose expanding shield anchor
Features and benefits
- Product recommended for applications requiring fire resistance
- Three-pieces expanding sleeve of maximum expansion provides optimal load and safety of use in any substrate
- Designed & manufactured for maximum performance
Product information
Size |
Product Code |
Anchor |
Fixture |
||
Diameter |
External diameter |
Length |
Hole diameter |
||
d |
dnom |
L |
df |
||
[mm] |
[mm] |
[mm] |
[mm] |
||
M6 |
R-RB-M06W |
6 |
12 |
45 |
6.5 |
M8 |
R-RB-M08W |
8 |
14 |
50 |
9 |
M10 |
R-RB-M10W |
10 |
16 |
60 |
11 |
M12 |
R-RB-M12W |
12 |
20 |
75 |
13 |
M16 |
R-RB-M16W |
16 |
25 |
115 |
17 |
M20 |
R-RB-M20W |
20 |
32 |
130 |
22 |
M24 |
R-RB-M24W |
24 |
38 |
150 |
26 |
For use also with
-
Cracked concrete C20/25-C50/60
-
Non-cracked concrete C20/25-C50/60
-
Unreinforced concrete
-
Reinforced concrete
-
Solid clay brick ≥ 20MPa
-
Hollow Lightweight Concrete Block LAC 5 ≥ 5MPa
-
Hollow Sand-lime Brick ≥ 15MPa
-
Concrete hollow floor block (eg. Teriva)
-
Hollow-core Slab C20/25
-
Hollow-core Slab C30/37-C50/60
-
Natural Stone (after site testing)
Applications
- Roller shutter doors
- Fire doors
- Wall plates
- Security grills
- Signs
- Manufacturing and installation of fencing
- Heavy machinery
- Pipework/duct work support
- Supporting guy ropes, stays and cables
- Supporting ladder restraints
Installation guide
- Drill a hole of required diameter and depth. Note: When fixing into brickwork, mortar joints should be avoided
- Remove debris and thoroughly clean hole with brush and pum
- Tap home with hammer until flush with surface
Installation data
Size |
M6 |
M8 |
M10 |
M12 |
M16 |
M20 |
M24 |
||
Thread diameter |
d |
[mm] |
6 |
8 |
10 |
12 |
16 |
20 |
24 |
Hole diameter in substrate |
d0 |
[mm] |
12 |
14 |
16 |
20 |
25 |
32 |
38 |
Installation torque |
Tinst |
[Nm] |
6.5 |
15 |
27 |
50 |
120 |
230 |
400 |
Min. hole depth in substrate |
h0 |
[mm] |
50 |
55 |
65 |
85 |
125 |
140 |
160 |
Min. installation depth |
hnom |
[mm] |
45 |
50 |
60 |
80 |
120 |
135 |
155 |
Min. substrate thickness |
hmin |
[mm] |
100 |
100 |
100 |
100 |
142.5 |
172.5 |
240 |
Min. spacing |
smin |
[mm] |
35 |
40 |
50 |
60 |
95 |
115 |
210 |
Min. edge distance |
cmin |
[mm] |
53 |
60 |
75 |
90 |
143 |
173 |
188 |
Contact us to get information about product availability and its price