Something went wrong... Please try again.
R-RBP Rawlbolt® - Bolt Projecting for use in hollow core slab and ceramic substrates
World's most popular all-purpose expanding shield anchor - bolt projecting version
Features and benefits
- RAWLBOLT® - first ever mechanical anchor in the world, forerunner of all of the later mechanical anchors
- For use in cracked and non-cracked concrete (ETA option 1), hollow-core slabs, flooring blocks and ceramics
- Three-pieces expanding sleeve of maximum expansion provides optimal load and safety of use in any substrate
- Wide range of diameters (M6 to M20)
Product information
Size |
Product Code |
Anchor |
Fixture |
Approval type |
|||
Diameter |
External diameter |
Length |
Max. thickness |
Hole diameter |
|||
d |
dnom |
L |
tfix |
df |
|||
[mm] |
[mm] |
[mm] |
[mm] |
[mm] |
- |
||
M6 |
R-RBP-M06/10W |
6 |
12 |
65 |
10 |
6,5 |
- |
R-RBP-M06/25W |
6 |
12 |
80 |
25 |
6,5 |
- |
|
R-RBP-M06/60W |
6 |
12 |
115 |
60 |
6,5 |
- |
|
M8 |
R-RBP-M08/10W |
8 |
14 |
75 |
10 |
9 |
- |
R-RBP-M08/25W |
8 |
14 |
90 |
25 |
9 |
- |
|
R-RBP-M08/60W |
8 |
14 |
125 |
60 |
9 |
- |
|
M10 |
R-RBP-M10/15W |
10 |
16 |
90 |
15 |
11 |
- |
R-RBP-M10/30W |
10 |
16 |
105 |
30 |
11 |
- |
|
R-RBP-M10/60W |
10 |
16 |
135 |
60 |
11 |
- |
|
M12 |
R-RBP-M12/15W |
12 |
20 |
110 |
15 |
13 |
- |
R-RBP-M12/30W |
12 |
20 |
125 |
30 |
13 |
- |
|
R-RBP-M12/75W |
12 |
20 |
170 |
75 |
13 |
- |
|
M16 |
R-RBP-M16/15W |
16 |
25 |
150 |
15 |
17 |
- |
R-RBP-M16/35W |
16 |
25 |
170 |
35 |
17 |
- |
|
R-RBP-M16/75W |
16 |
25 |
210 |
75 |
17 |
- |
|
M20 |
R-RBP-M20/15W |
20 |
32 |
170 |
15 |
22 |
- |
R-RBP-M20/30W |
20 |
32 |
185 |
30 |
22 |
- |
|
R-RBP-M20/100W |
20 |
32 |
255 |
100 |
22 |
- |
|
M24 |
R-RBP-M24/75W |
24 |
38 |
255 |
75 |
26 |
- |
Base material
-
Solid clay brick ≥ 20MPa
-
Hollow Lightweight Concrete Block LAC 5 ≥ 5MPa
-
Hollow Sand-lime Brick ≥ 15MPa
-
Concrete hollow floor block (eg. Teriva)
-
Hollow-core Slab C20/25
-
Hollow-core Slab C30/37-C50/60
For use also with
-
Cracked concrete C20/25-C50/60
-
Non-cracked concrete C20/25-C50/60
-
Unreinforced concrete
-
Reinforced concrete
-
Natural Stone (after site testing)
Applications
- Roller shutter doors
- Fire doors
- Steelwork
- Security grills
- Heavy machinery
- Pipework/duct work support
Installation guide
- Drill a hole of required diameter and depth
- Remove nut and washer and insert anchor into hole. Tap home with hammer until flush with surface
- Position fixture over the projecting bolt
- Add washer and nut and tighten to recommended torque
Installation data
Size |
M6 |
M8 |
M10 |
M12 |
M16 |
M20 |
M24 |
||
Thread diameter |
d |
[mm] |
6 |
8 |
10 |
12 |
16 |
20 |
24 |
Hole diameter in substrate |
d0 |
[mm] |
12 |
14 |
16 |
20 |
25 |
32 |
38 |
Min. installation depth |
hnom |
[mm] |
45 |
50 |
60 |
80 |
120 |
135 |
155 |
Min. hole depth in substrate |
h0 |
[mm] |
50 |
55 |
65 |
85 |
125 |
140 |
160 |
Wrench size |
Sw |
[mm] |
10 |
13 |
17 |
19 |
24 |
30 |
36 |
SOLID SUBSTRATES | |||||||||
Installation torque |
Tinst |
[Nm] |
6.5 |
15 |
27 |
50 |
120 |
230 |
- |
Min. substrate thickness |
hmin |
[mm] |
100 |
100 |
100 |
100 |
142 |
172 |
- |
Min. spacing |
smin |
[mm] |
35 |
40 |
50 |
60 |
95 |
115 |
- |
Min. edge distance |
cmin |
[mm] |
53 |
60 |
75 |
90 |
143 |
173 |
- |
CERAMIC AND HOLLOW SUBSTRATES | |||||||||
Installation torque |
Tinst |
[Nm] |
3 |
5 |
8 |
10 |
15 |
20 |
- |
Min. spacing |
smin |
[mm] |
100 |
100 |
100 |
100 |
100 |
115 |
- |
Min. edge distance |
cmin |
[mm] |
100 |
100 |
100 |
100 |
143 |
173 |
- |
Installation torque |
Tinst |
[Nm] |
- |
- |
- |
- |
- |
- |
400 |
Min. substrate thickness |
hmin |
[mm] |
- |
- |
- |
- |
- |
- |
240 |
Min. spacing |
smin |
[mm] |
- |
- |
- |
- |
- |
- |
210 |
Min. edge distance |
cmin |
[mm] |
- |
- |
- |
- |
- |
- |
188 |
Contact us to get information about product availability and its price