Something went wrong... Please try again.
R-SPL SafetyPlus - Loose Bolt
High performance mechanical anchor - loose bolt option
Features and benefits
- High performance in non-cracked concrete confirmed by ETA Option 7
- Design of SafetyPlus allows for easy through fixing
- Integral controlled collapse and anti-rotation feature ensures fixture is firmly secured
- Unique zig-zag feature provides balanced expansion, ensuring secure setting and maximised load-bearing capacity
- Case-hardened nut with optimum taper angle for enhanced expansion
- Fire resistant
Product information
Size |
Product Code |
Anchor |
Fixture |
|||
Thread size |
External diameter |
Length |
Max. thickness |
Hole diameter |
||
d |
dnom |
L |
tfix |
df |
||
[mm] |
[mm] |
[mm] |
[mm] |
[mm] |
||
M8 |
R-SPL-08090/15 |
8 |
12 |
90 |
15 |
14 |
R-SPL-08110/40 |
8 |
12 |
110 |
40 |
14 |
|
M10 |
R-SPL-10105/20 |
10 |
15 |
105 |
20 |
17 |
R-SPL-10120/40 |
10 |
15 |
120 |
40 |
17 |
|
R-SPL-10140/60 |
10 |
15 |
140 |
60 |
17 |
|
M12 |
R-SPL-12120/25 |
12 |
18 |
120 |
25 |
20 |
R-SPL-12150/50 |
12 |
18 |
150 |
50 |
20 |
|
M16 |
R-SPL-16145/25 |
16 |
24 |
145 |
25 |
26 |
R-SPL-16170/50 |
16 |
24 |
170 |
50 |
26 |
|
M20 |
R-SPL-20175/30 |
20 |
28 |
175 |
30 |
30 |
Base material
-
Non-cracked concrete C20/25-C50/60
-
Unreinforced concrete
-
Reinforced concrete
For use also with
-
Natural Stone (after site testing)
Applications
- Structural steel
- Masonry support
- Cladding restraints
- Road Signs
- Heavy machinery
- Racking systems
- Industrial doors
- Safety barriers
Installation guide
- Drill a hole of required diameter and depth
- Clear the hole of drilling dust and debris (using blowpump or equivalent method)
- Insert anchor through fixture into hole and tap until required installation depth is achieved
- Tighten to the recommended torque
Installation data
Size |
M8 |
M10 |
M12 |
M16 |
M20 |
||
Thread diameter |
d |
[mm] |
8 |
10 |
12 |
16 |
20 |
Hole diameter in substrate |
d0 |
[mm] |
12 |
15 |
18 |
24 |
28 |
Installation torque |
Tinst |
[Nm] |
25 |
50 |
80 |
180 |
275 |
Wrench size |
Sw |
[mm] |
13 |
17 |
19 |
24 |
30 |
Min. hole depth in substrate |
h0 |
[mm] |
85 |
95 |
105 |
130 |
160 |
Min. installation depth |
hnom |
[mm] |
70 |
80 |
90 |
110 |
130 |
Min. substrate thickness |
hmin |
[mm] |
100 |
105 |
120 |
150 |
188 |
Min. spacing |
smin |
[mm] |
60 |
70 |
80 |
100 |
125 |
Min. edge distance |
cmin |
[mm] |
90 |
105 |
120 |
150 |
186 |
Downloads
- R-SPL SafetyPlus - Loose Bolt - Technical Data Sheet
- EC Certificate - SafetyPlus_EN.pdf
- ETAS-11-0126_SafetyPlus_2017_EN.pdf
- UKTA-0836-22_6101_2022_R-SPL_EN.pdf
Need documents for other product? Visit our Technical Library.
go to libraryContact us to get information about product availability and its price